您的当前位置:首页正文

诺瓦科技多功能卡MFN300规格书英文版

2021-04-19 来源:易榕旅网


XI'NA OSpecifications NTSAVMultifunction Card MFN300

HCET RAOC.T,L.D

Product images provided in this file are for reference only, and the actual products shall prevail.

Rev2.1.0 NS110100087

Features

Nova M3 MFN300 is a multifunction card with a variety of auxiliary functions. It has the following features:

1) RS232 serial or Gigabit Ethernet port communication.

2) Ethernet port connection between two receiving cards or at the end. 3) Timer function which is able to replace timer and delayer. 4) Temperature detection of power distribution box. 5) Humidity detection of power distribution box. 6) Audio output.

7) 4-way light sensor connection to achieve automatic brightness

adjustment.

8) Temperature and humidity module connection. 9) 8-way power switch control.

'IXNA NOTSAV HCET RAOC.T,L.D

www.novastar.tech Page 1

Dimensions

Thickness of the board is about 1.6mm. The overall thickness (board thickness+thickness of the components on front and back side) is about 20mm.

'IXNA NOTSAV HCET RAOC.T,L.DUnit: mm.

www.novastar.tech Page 2

Appearance

Note: Product images provided in this file are for reference only, and the actual products shall prevail.

'IXNA NOTSAV HCET RAOC.T,L.D

www.novastar.tech Page 3

Connection

 Connect multifunction card to computer directly by RS232 serial

cable.

 Connect multifunction card between sending card (or independent

controller) and the first receiving card.

 Connect multifunction card between any two receiving cards.

 Connect multifunction card to the last receiving card.

'IXNA

NOTSAV HCET RAOC.T,L

.D

www.novastar.tech Page 4

Software Configuration

Run NovaLCT-Mars control software and click Function Card button to open Function Card Management page.

Use the menu in above Figure to configure multifunction card, including Add, Remove, Rename a Function card, Modify Serial Port and Replace

'IXNAAdd:

Serial Port.

NOTSAV HCET RAOC.T,L.D

 Serial port: Add a multifunction card which is connected to the serial

port.

 Ethernet port: Add a multifunction card which is connected to the

Ethernet port.

Remove: Remove the selected node which could be a multifunction card, Ethernet port, sending card or serial port.

www.novastar.tech Page 5

Rename: Rename the selected multifunction card. Serial port operation: Click

icon to select Modify Serial Port or Replace Serial Port.

 Modify Serial Port: Set the selected serial port as one that no

multifunction card has been configured for.

 Replace Serial Port: Replace the selected serial port with one which

is configured but the configured device type is different from that of actually connected, or is actually not connected.

Note: The icon is only available when the following requirements are satisfied: The selected node is a serial port; the device connected to it does not match the one configured to it, or the serial port is not connected.

www.novastar.tech Page 6

'IXNA NOTSAV HCET RAOC.T,L.D

Specifications

DC 3.3V~5.5V 0.38A 2.5W -20℃~75℃ 0%RH~90%RH 144.0mm×94.8mm×20.0mm 164.4g Input voltage Rated current Rated power consumption Operating temperature Operating humidity Dimension Net weight

'IXNA NOTSAV HCET RAOC.T,L.Dwww.novastar.tech Page 7