Hard Disk Drive Kit
User’s Guide
Fifth Edition
Manufacturing No. E5071-90132
April 2009
Notices
The information contained in this document is subject to change without notice.This document contains proprietary information that is protected by copyright.All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of the Agilent Technologies.© Copyright 2007, 2008 Agilent Technologies
Manual Printing History
The manual’s printing date and part number indicate its current edition. The printing date changes when a new edition is printed. (Minor corrections and updates that are
incorporated at reprint do not cause the date to change.) The manual part number changes when extensive technical changes are incorporated.Oct 2006 May 2007 Jun 2007 December 2008 April 2009
First EditionSecond EditionThird EditionFourth EditionFifth Edition
Typeface Conventions
Sample (bold) Sample (Italic)
key
Boldface type is used when a term is defined or emphasis.
Italic type is used for emphasis.
Indicates a hardkey (key on the front panel or external keyboard) labeled “Sample.” “key” may be omitted.
Indicates a menu/button/box on the screen labeled “Sample” which can be selected/executed by clicking. “menu,” “button,” or “box” may be omitted.
Indicates a block (group of hardkeys) or a toolbar (setup toolbar) labeled “Sample.”
Indicates a sequential operation of Sample 1, Sample 2, and Sample 3 (menu, button, or box). “-” may be omitted.
Sample menu/button/box
Sample block/toolbar
Sample 1 - Sample 2 - Sample 3
2
1 General Information
This chapter describes the Hard Disk Drive Kit, contents of the kit, and required tools to install the Option 018 into the Agilent E5071C.
3
General Information
Option 018 Hard Disk Drive Kit
Option 018 Hard Disk Drive Kit
The purpose of this kit is to install the option 018 into the Agilent E5071C.
Contents of the Agilent E5071CU Option 018 Upgrade Kit
The kit includes the parts listed in Table 1-1. If anything is missing, contact the nearest Agilent Technologies office.
Table 1-1
Contents of the Agilent E5071CU Option 018 Upgrade Kit
Description
Upgrade Manual (This manual)Hard Disk for E5071C
Qty.11
4Chapter 1
2 Option Installation
This chapter describes the procedure to install the option 018 into the Agilent E5071C.
5
Option InstallationIntroduction
Introduction
This chapter describes the procedure to install Option 018 into the E5071C. The procedure consists of the following items.••••••
Installation RequirementRemoval ProcedureReplacement Procedure
Writing System Correction Data of Backup Memory to Removable HDDInitial Registration of E5071CReconfiguring Touch Panel Settings
Update Procedure for Hard disk Type 1
This procedure is for Non-screw type hard disk (Type 1).
Installation Requirement
•
0960-2562 Key for Hard Disk Carrier
Preparation
It is required to replace the front plate before installing this removable hard disk to Type 1 user’s system.
Step 1.Remove the two stickers (item 1).
Figure 2-1
1Item 1: E5070-87303
Step 2.Remove the two TORX T10 screws (item 2) that are fastening the frnt plate.
6Chapter 2
Figure 2-2
Figure 2-3
Figure 2-4
Option Installation
Update Procedure for Hard disk Type 1
2Item 2: 0515-2146
Step 3.Fasten the front plate for Typ 1 user (item 3) with TORX T10 screw (item 4).
3Item 3: E5070-00657
4Item 4: 0515-2146
Step 4.Put the stickers (item 5) on the TORX T10 screws in the front plate..
Chapter 2 7
Option Installation
Update Procedure for Hard disk Type 1
Figure 2-5
5Item 5: E5070-87303
Removal Procedure
Step 1.Turn off the power.
Step 2.Inset the key in the lock and turn crockwise.
Step 3.Push the button under the lock and remove the hard disk.
Replacement Procedure
Step 1.Insert the hard disk into the slot.Step 2.Turn the key to the left until it is locked.Step 3.Remove the key.
8Chapter 2
Option Installation
Update Procedure for Hard disk Type 1
Writing System Correction Data of Backup Memory to Removable HDD
The following is a description of the procedures to write the system correction data stored in the backup memory to the mounted removable HDD.
Step 1.Turn on the E5071C.
CAUTION
The function for Factory image making window is only displayed when the E5071C is turned on for the first time.
It is required to make a factory image based on “Procedure to execute the factory recovery (HDD Revision: CN924 or below)” of the average of “System Recovery” before advancing to Step 2.
Step 2.Press
Step 3.Press Load Project... on the softkey menu.
Step 4.A dialog box appears to allow you to select a program to be loaded. Select
RestoreSysCorFile.vba from the D:\\Agilent\\Service folder, and then press Open button.Step 5.Press
Step 6.RestoreSysCorFile dialog box appears (Figure 2-6). Click OK.
Figure 2-6
RestoreSysCorFile Dialog Box
CAUTIONOnce the program has ended, restart the E5071C to enable the system correction data.
Step 7.After restart, the screen for initial registration appears. Execute initial registration. For
information on the execution procedure, refer to “Initial Registration Procedure (HDD Revision: CN924 or below)” on page 39.
NOTE
If the touch screen does not work after the installaiton, refer to “Reconfiguring Touch Panel Settings” on page 37.
Chapter 2 9
Option Installation
Update Procedure for Hard Disk Type 2
Update Procedure for Hard Disk Type 2
This procedure is for screw type hard disk (Type 2).
Installation Requirement
•
5188-4426 Key for Hard Disk Carrier
Removal Procedure
Step 1.Turn off the power.
Step 2.Inset the key in the lock and turn anti-clockwise.Step 3.Open the screw in clockwise direction.Step 4.Press the button under the screw.Step 5.Remove the hard disk.
Replacement Procedure
Step 1.Insert the hard disk into the slot.
Step 2.Turn the screw in anti-clockwise direction until it is locked..Step 3.Turn the key to the right until it is locked.Step 4.Remove the key.Step 5.Turn on the E5071C.
10Chapter 2
Option Installation
Update Procedure for Hard Disk Type 2
Writing System Correction Data of Backup Memory to Removable HDD
The following is a description of the procedures to write the system correction data stored in the backup memory to the mounted removable HDD.
Step 1.Turn on the E5071C.Step 2.Press
Step 3.Press Load Project... on the softkey menu.
Step 4.A dialog box appears to allow you to select a program to be loaded. Select
RestoreSysCorFile.vba from the D:\\Agilent\\Service folder, and then press Open button.Step 5.Press
Step 6.RestoreSysCorFile dialog box appears (Figure 2-7). Click OK.
Figure 2-7
RestoreSysCorFile Dialog Box
CAUTIONOnce the program has ended, restart the E5071C to enable the system correction data.
Step 7.After restart, the screen for initial registration appears. Execute initial registration. For
information on the execution procedure, refer to “Initial Registration Procedure (HDD Revision: CN925 or above)” on page 35 for HDD revision: CN925 or above. If HDD revision is CN924 or below, refer to “Initial Registration Procedure (HDD Revision: CN924 or below)” on page 39
NOTE
If the touch screen does not work after the installaiton, refer to “Reconfiguring Touch Panel Settings” on page 37.
Chapter 2 11
Option InstallationSystem Recovery
System Recovery
By executing system recovery, you can return the system of the E5071C (the Windows operating system) to the factory state (at the time of purchase*1).
NOTE
System recovery is a function of Windows and not a function of the E5071C Firmware. The system recovery procedure is different in accordance with the HDD revision. The HDD revision can be checked using the following procedure:
Step 1.In E5071C, from Windows Start Menu, click on My Computer.Step 2.The volume label for C: drive is displayed in Hard Disc Drive area.
CAUTION
Strictly follow the steps described below. If you do any operation other than the following steps, the system may not be recovered.
Types of system recoveries
The following 2 types of system recoveries are available.RFactory recovery
Returns the contents of the C drive to the factory state.
RUser recovery (available only when HDD revision is CN924 or below)
Returns the contents of the C and D drives to a user-specified state. To use this function, you must prepare for recovery in advance. For information on the
preparation, see “Procedure to execute the factory recovery (HDD Revision: CN924 or below)” on page 16 for information on the execution, see “Procedure to execute the factory recovery (HDD Revision: CN924 or below)” on page 16.
*1.If the hard disk failed and has been replaced after purchase, the state when the replacement was performed is recovered.
12Chapter 2
Option InstallationSystem Recovery
Notes on executing the factory recovery function
Executing the factory recovery function causes the following conditions:
RIn addition to the Windows operating system, the following settings of the E5071C are
returned to the factory state.
•••
Network settingGPIB settingPrinter setting
RThe driver for the supported printer installed after purchase is deleted. RYou need to execute initial registration again.
RThe firmware revision you installed remains even if you perform factory recovery.Files you created using the save function (files in the D drive) are not affected, but we recommend backing them up before executing system recovery for precautionary
purposes. For more information on backup, refer to “Backing Up the Data” as described in E5071C Online Help.
Chapter 2 13
NOTE
Figure 2-8
Figure 2-9
Option InstallationSystem Recovery
Procedure to execute the factory recovery (HDD Revision: CN925 or above)
The recovery function for Factory image is only loaded.The User back up function is not available.
Step 1.Turn ON the E5071C.
Step 2.The boot option is displayed. Use the downward arrow key to select the “Agilent Recovery
Solution” and press EnterStep 3.Windows PE starts up and “Agilent Recovery Program” window is displayed. Press 1, and
then press Enter.
Agilent Recovery Program(1/1)
Step 4.A warning message is displayed. Press 1, and then press Enter.
Agilent Recovery Program(1/2)
Step 5.Caution is displayed. Press 1, and then press Enter.
14Chapter 2
Option InstallationSystem Recovery
Figure 2-10
Agilent Recovery Program(1/3)
Step 6.Recovery function is performed.
Step 7.A message box appears after the completion of recovery process. Press any key to
continue.
Figure 2-11
Agilent Recovery Program(1/4)
Step 8.When the recovery is finished, E5071C restarts.
Step 9.After restart, the screen for initial registration appears. Execute initial registration. For
information on the execution procedure, refer to “Initial Registration Procedure (HDD Revision: CN925 or above)” on page 35.
NOTE
If the touch screen does not work after System Recovery, refer to “Reconfiguring Touch Panel Settings” on page 37.
Chapter 2 15
Option InstallationSystem Recovery
Procedure to execute the factory recovery (HDD Revision: CN924 or below)
This section describes how to return the contents of the C drive to the factory state.
NOTE
You need a keyboard for this operation.
Step 1.Shut down the E5071C.
Step 2.Disconnect all of the USB device from the USB ports.Step 3.Connect the keyboard to the E5071C.
Step 4.Press the standby switch of the E5071C to turn it on.
Step 5.When the screen as shown in the figure below appears, press F11 of the keyboard.
Starting Acronis Loader...Press F11 for Acronis Startup Recovery Manager...e5071cse1055CAUTION
Press F11 only once. If you press F11 twice or more and a screen which is not mentioned in this manual appears, reboot the instrument and restart the process from the first.After several seconds, the next screen appears automatically even if you do not press any key, so do not miss it.
After Step 5, if the E5071C freezes with the cursor does not blink, turn the off and remove unnecessary USB devices. Then, replace the keyboard with a PS/2 keyboard to execute the process again.
Step 6.Select Restore.
NOTE
NOTE
16Chapter 2
Option InstallationSystem Recovery
Figure 2-12
Activate Acronis Startup Recovery Manager
e5071cse1079Step 7.A confirmation dialog box is displayed. Push the enter to select Yes to start the recovery of
the factory backup. The recovery takes a few minutes depending on the amount of data.
Figure 2-13
Recover Factory Backup
e5071cse1034Step 8.When the recovery is finished, push the enter select OK. The E5071C restarts
automatically.Step 9.After restart, the screen for initial registration appears. Execute initial registration. For
information on the execution procedure, refer to “Initial Registration Procedure (HDD Revision: CN924 or below)” on page 39.Step 10. Execute the calibration of the touch screen. For information on the execution procedure,
refer to “Calibration of the Touch Screen” on page 41.
CAUTION
Never turn off the power during the system recovery because doing so may cause serious damage to the E5071C.
Chapter 2 17
Figure 2-14
Option InstallationSystem Recovery
Procedure to create the user backup image (HDD Revision: CN924 or below)
This section describes how to create the user backup image. The C and D drives’ contents saved in this procedure are recalled when the user recovery function is executed.
Step 1.Close the E5071C application by pressing System > Service Menu > Exit. Step 2.Close all other applications you currently open.
Step 3.From the Windows start menu, select All Programs > Acronis > Acronis True Image. Step 4.Click “No, Thanks” button.
Recover User Backup
e5071cse1080Step 5.Click Backup
e5071cse1125 18Chapter 2
Option InstallationSystem Recovery
Step 6.Click Next button.
e5071cse1126Step 7.Select “The entire disk contents or individual partition,” then click Next button.
e5071cse1127Chapter 2 19
Option InstallationSystem Recovery
Step 8.Select the C drive and D drive.
e5071cse1128Step 9.Select the destination folder and input a file name, then click Next button. It is
recommended to save the file to a directory which has enough space like the E drive. Also, never save the contents of the drive to the C, D or F drive.
e5071cse1129 20Chapter 2
Option InstallationSystem Recovery
Step 10.Select “Set the options manually” and click Next button.
e5071cse1130Step 11.Select “Backup priority” in the left field and “High” in the right field, then click Next
button.
e5071cse1131Chapter 2 21
Option InstallationSystem Recovery
Step 12.If necessary, input comments and click Next button. The comments can be omitted.
e5071cse1132Step 13.Click Proceed button.
e5071cse1133 22Chapter 2
Option InstallationSystem Recovery
Step 14.The following screen appears during backup.
e5071cse1134Step 15.The following screen appears when the user backup image was created. Click OK.
e5071cse1135CAUTION
Never turn off the power during creating the user backup image because doing so may cause serious damage to the E5071C.
Chapter 2 23
Option InstallationSystem Recovery
Procedure to execute the user recovery function (HDD Revision: CN924 or below)
Returns the contents of the C and D drives to a user-specified state. To use this function, you must create the user backup image in advance. For more information, see the
description “Procedure to create the user backup image (HDD Revision: CN924 or below)” on page 18.
Step 1.Close the E5071C application by pressing System > Service Menu > Exit. Step 2.Close all other applications you currently open.
Step 3.From the Windows start menu, select All Programs > Acronis > Acronis True Image. Step 4.Click “No, Thanks” button.
e5071cse1080Step 5.Click Recovery.
e5071cse1136 24Chapter 2
Option InstallationSystem Recovery
Step 6.Click Next button.
e5071cse1137Step 7.Select the saved backup image file, then click Next button.
e5071cse1138Chapter 2 25
Option InstallationSystem Recovery
Step 8.Select “Restore disks or partitions,” then click Next button.
e5071cse1139Step 9.Select the C drive, then click Next button.
e5071cse1143 26Chapter 2
Option InstallationSystem Recovery
Step 10.Select the C drive to restore, then click Next button.
e5071cse1144Step 11.Select “Active” and click Next button.
e5071cse1145Chapter 2 27
Option InstallationSystem Recovery
Step 12.Click Next button.
e5071cse1146Step 13.Select “Yes, I want to assign a logical drive letter to the restored partition” and click Next
button.
e5071cse1147 28Chapter 2
Option InstallationSystem Recovery
Step 14. Select “Yes, I want to restore another partition or hard disk drive,” then click Next button.
e5071cse1148Step 15.Select the D drive to restore, then click Next button.
e5071cse1149Chapter 2 29
Option InstallationSystem Recovery
Step 16.Select the D drive to restore, then click Next button.
e5071cse1150Step 17.Select “Logical” and click Next button.
e5071cse1151 30Chapter 2
Option InstallationSystem Recovery
Step 18.Click Next button.
e5071cse1152Step 19.Select “Yes, I want to assign a logical drive letter to the restored partition,” then click Next
button.
e5071cse1153Chapter 2 31
Option InstallationSystem Recovery
Step 20.Select “No, I do not.” and click Next button.
e5071cse1154Step 21.Select “Set the options manually” and click Next button.
e5071cse1155Step 22.Select “Restoration Priority” in the left field and “High” in the right field, then click Next
32Chapter 2
Option InstallationSystem Recovery
button.
e5071cse1156Step 23.Click Proceed button.
e5071cse1157Chapter 2 33
Option InstallationSystem Recovery
Step 24.Click Reboot button.
e5071cse1158CAUTION
Never turn off the power during the recovery of the user backup image because doing so may cause serious damage to the E5071C.
Step 25.After boot up, perform “Initial Registration of E5071C” on page 35 and “Calibration of the
Touch Screen” on page 41.
34Chapter 2
Option Installation
Initial Registration of E5071C
Initial Registration of E5071C
When you start up the E5071C at the first time, you need to perform the initial registration of the Windows XP operating system of the E5071C. There are two procedures in accordance with the HDD revision.
NOTE
It is not possible to check the HDD revision installed on your E5071C before Windows is booted. Therefore you should follow the procedure which you see on the E5071C.You cannot use the front panel keys during the initial registration of the E5071C therefore connect the mouse and the keyboard before turning on the power.
If you perform the following procedure incorrectly, a message asking you whether to return to the previous registration screen and perform the registration appears. In this case, follow the instruction to return to the previous registration screen.
NOTE
NOTE
Initial Registration Procedure (HDD Revision: CN925 or above)
Step 1.Turns on the E5071C.
Step 2.The Windows XP Professional Setup wizard appears. Click the Next > button (Figure
2-15).
Figure 2-15
Windows XP Professional Setup wizard
e5071cse1073Chapter 2 35
Option Installation
Initial Registration of E5071C
Step 3.In the Windows XP Professional Setup dialog box, read the license agreement, then select
the I accept this agreement box and click the Next > button (Figure 2-16).
Figure 2-16
Windows XP Professional Setup dialog box (1/2)
Figure 2-17
e5071cse1074Step 4.In the next dialog box, input agena in the Name box. Then, click the Next> button (Figure
2-17).
Windows XP Professional Setup dialog box (2/2)
e5071cse1075Step 5.The E5071C restart automatically.
Step 6.The Agilent Recovery Image Setup screen (Figure 2-18) appears. Click OK to proceed.
36Chapter 2
Option Installation
Initial Registration of E5071C
Figure 2-18
Agilent Recovery Image Setup Screen(1/1)
Step 7.A progress bar appears (Figure 2-19) indicating the progress of the Recovery Image setup.
The complete process takes less than 5 minutes to finish.
Figure 2-19
Agilent Recovery Image Setup Screen(1/2)
Step 8.A message dialog box appears after the completion of the Recovery Image Setup
procedure. The dialog box disappears automatically after a few seconds.Step 9.E5071C firmware is executed, then the measurement display appears.
NOTE
If the touch screen does not work after Initial Registration, refer to “Reconfiguring Touch Panel Settings” on page 37.
Reconfiguring Touch Panel Settings
Step 1.In E5071C, right click My Computer.
Step 2.Select Properties. The System Properties dialog box appears.Step 3.Select Hardware tab.
Step 4.Click Device Manager. The Device Manager dialog box appears.Step 5.Select Ports (COM & LPT).
Step 6.Check if two Communication Port (COM1) are displayed.
Chapter 2 37
Option Installation
Initial Registration of E5071C
Step 7.Right click and select Unistall for both the COM1 ports.
Step 8.The Confirm Device Removal message box appears. Click OK.Step 9.Reboot the instrument.
38Chapter 2
Option Installation
Initial Registration of E5071C
Initial Registration Procedure (HDD Revision: CN924 or below)
Step 1.Turns on the E5071C.
Step 2.The Windows XP Professional Setup wizard appears. Click the Next > button (Figure
2-20).
Figure 2-20
Windows XP Professional Setup wizard
Figure 2-21
e5071cse1073Step 3.In the Windows XP Professional Setup dialog box, select the I accept this agreement box
and click the Next > button (Figure 2-21).
Windows XP Professional Setup dialog box (1/2)
e5071cse1074Step 4.In the next dialog box, input agena in the Name box. Then, click the Next> button (Figure
2-22).
Chapter 2 39
Option Installation
Initial Registration of E5071C
Figure 2-22
Windows XP Professional Setup dialog box (2/2)
e5071cse1075Step 5.After a while, the E5071C restart automatically.
40Chapter 2
Option Installation
Calibration of the Touch Screen
Calibration of the Touch Screen
After E5071C measurement screen appears, you have to calibrate the touch screen. Follow the procedure described below to calibrate the touch screen.
Step 1.Press
.
Step 2.Press Service Menu.Step 3.Press Test Menu.
Step 4.Press Adjust Touch Screen.
The touch screen calibration screen (Figure 2-23) appears.
Figure 2-23
Touch Panel Calibration Screen
e5071cse1078Step 5.Touch the x mark on the upper left with your finger. The mark x appears also on the upper
right, lower left, and lower right. Touch the x marks in that order with your finger.
Touching the four locations described above with your finger automatically concludes the touch screen calibration.
NOTE
With no operation on the touch screen calibration screen for a preset time, it automatically closes and the previous measurement screen reappears.
Chapter 2 41
REGIONAL SALES AND SUPPORT OFFICES
For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir. You can also contact one of the following centers and ask for a test and measurement sales representative. 21/01/2004
United States:
Test and Measurement Call Center (tel) 1 800 452-4844 (fax) 1 888 900-8921
Canada:
Test and Measurement Call Center (tel) 1 877 894-4414 (fax) 1 888 900-8921
China:
(tel) 800 810-0189 (fax) 800 820-2816
Europe:
(tel) (31 20) 547-2323 (fax) (31 20) 547-2390
Japan: Call Center
(tel) 0120 421-345 (tel) (81) 426 56-7832 (fax) (81) 426 56-7840
Korea:
(tel) (82 2) 2004-5004 (fax) (82 2) 2004-5115
Latin America:
(tel) (305) 269-7500 (fax) (305) 269-7599
Taiwan:
(tel) 0800 047 866 (fax) 0800 286 331
Australia/New Zealand:
(tel) (61 3) 9210-5555 (Australia) (fax) (61 3) 9210-5899
(tel) (64 4) 939-0636 (New Zealand) (fax) (64 4) 972-5364
Asia Pacific:
(tel) (65) 6375-8100 (fax) (65) 6836-0252
Email: tm_asia@agilent.com
因篇幅问题不能全部显示,请点此查看更多更全内容